ABSTRACT
Aim:
It is important to determine which of the treatment options applied in the emergency department is more effective and usable in coagulation pathologies. In this study, we aimed to evaluate the efficacy and safety of fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC), which are used in the treatment of high hemostasis parameters in the emergency department.
Methods:
This retrospective study included 103 patients who were admitted to the emergency department between January 2019 and December 2020. All data were obtained from the hospital automation system. While the patients were divided into two groups (FFP-PCC) according to the treatment option they received, they were also divided into three groups (DED-RSH-ISH) according to hospitalization status. With this data, treatment efficacy and outcomes were analyzed.
Results:
The mean age of 103 patients was 67.31±13.17 years, with 58 (56%) females and 45 (44%) males. 51 (49.5%) of the cases received FFP and 52 (50.5%) PCC treatment. While the international normalized ratio (INR)1 value before the treatment was 7.56±4.09 and 2.42±1.01 after the treatment in the FFP group, the INR1 value was 10.12±5.18 and INR2 1.95±0.71 in the PCC group. The percentage of INR decrease was 60.28±19.76 (%) in the FFP group, and 73.41±17.42 (%) in the PCC group (p=0.001). In receiver operating characteristic curve analysis, the sensitivity and specificity of FFP and PCC decreased significantly in INR%.
Conclusion:
FFP is preferable in this regard to FFP because it is easier to apply, has a faster effect, and provides better values in coagulation parameters.
Introduction
In the emergency department, abnormal bleeding can be seen in patients due to defective hemostasis mechanisms. In addition to drug use, conditions such as liver disease and kidney failure can increase the potential for abnormal bleeding (1). In recent years, there has been an increase in the number of patients admitted to the emergency department with warfarin-related complications. Warfarin is important for emergency physicians because it is associated with bleeding complications when the therapeutic range is exceeded and its interactions with drugs are frequent (2). The frequency of emergency department admissions as a result of developing complications is also mentioned. It is also stated that the risk of life-threatening or fatal bleeding is between 1-3% (3,4).
The International Normalized Ratio (INR) is used as a follow-up parameter for warfarin treatment effectiveness. These INR values reflect the extent of anticoagulation that minimizes the risk of serious bleeding while reducing morbidity from thromboembolic disease. For most indications, the INR range of 2-3 is used. Patients with high INR values, asymptomatic or with accompanying bleeding findings, are frequently evaluated in the emergency department (5,6).
To achieve this, fresh frozen plasma (FFP) and prothrombin complex concentrates (PCC) are used today. Both have their advantages and disadvantages. FFP is plasma obtained by separating whole blood from erythrocytes and platelets and freezing within eight hours after collection. FFP is suitable for rapid replacement in multiple coagulation deficiencies such as hepatic failure, warfarin overdose, disseminated intravascular coagulation, and massive transfusion in patients with bleeding. While it has very positive effects when used by its indication, it can also lead to serious complications related to transfusion when used off-label (7). In addition, PCC can be given to patients with high INR to relieve symptoms or in cases where an urgent invasive procedure is required. The use of PCCs containing vitamin K-dependent coagulation factors is also recommended, especially in order to reverse the anticoagulant effect associated with the use of warfarin, due to its advantages such as rapid improvement in INR level, shorter administration time, and higher amount of factors than normal plasma (8-10).
It is seen that the use of PCC has become widespread, especially recently, and accordingly, studies conducted both in isolation and in the form of comparisons with FFP have increased. These studies include trauma or surgical process patients as well as emergency department patients. Both applications are used as treatment options for bleeding disorders, which are a very common reason for admission. Opinions are different about their supply, application times, and ability to provide the desired effectiveness, and the researches continue increasingly. This important and common issue has also encouraged us to work on which treatment is more appropriate (11-14).
In our study, we aimed to evaluate the effects of demographic characteristics, warfarin use, admission complaints, as well as the effects of FFP and PCC treatments on hemostasis values of patients with high INR levels in the emergency department.
Methods
Compliance with Ethical Standards
The study was carried out in the University of Health Sciences Turkey, Istanbul Bagcilar Training and Research Hospital Emergency Medicine Clinic, in accordance with the Helsinki Declaration rules, after the approval of the local ethics committee (decision date and number: 03.05.2021-190).
Study Design and Population
In this retrospective study, 103 patients who were older than 18 years old, had an INR value above 2, were treated with FFP or 4-factor PCC (Cofact®, defined as the third generation) and did not meet any of our exclusion criteria, were admitted to the emergency department between January 2019 and December 2020 (58 women, 45 men; mean age 67.31±13.17 years; range 24-88 years, 56.3% women) were included.
Patients with known chronic liver and kidney disease, severe anemia, and malignancy, in addition to patients with deficiencies in admission and discharge hemostasis parameters and observation data, were excluded from the study.
Patients were divided into 2 groups according to whether they received FFP or PCC treatment in the emergency department. In addition, the patients were divided into 3 groups according to their discharge from the emergency department and hospitalization in the service and intensive care units.
Demographic information of patients from hospital records, comorbidity status, admission complaints, drug use, admission complaints, FFP or PCC treatment status, doses, type of complication if developed (within 24 hours), prothrombin time (PT) before and after treatment, activated Partial Thromboplastin Time (aPTT), INR values, and outcome patterns of the patients (admission, discharge, and death) were recorded. Pre-treatment values were recorded as aPTT1, PT1, INR1, and post-treatment values were recorded as aPTT2, PT2, INR2, according to the results of the sample taken at the 15th minute after treatment. The percentages of decrease in INR were calculated and recorded as “decrease of INR%”.
Statistical Analysis
Version 21.0 (released in 2012 by IBM Corp.) of the IBM SPSS Statistics for Windows program (Armonk, NY: IBM Corp.) was used in the analysis. Continuous data were presented as mean standard deviation, while categorical data were presented as a percentage (%). The Shapiro-Wilk test was used to investigate the conformity of the data to the normal distribution. In the comparison of normally distributed groups, an independent sample t-test analysis was used for cases with two groups. The Mann-Whitney U test was used for cases with two groups in the comparison of the groups that did not conform to the normal distribution. For the normally distributed variables, Pearson correlation coefficients were calculated to determine the direction and size of the relationship (correlation) between the variables. Chi-square analyses were used in the analysis of the created cross tables. A receiver operating characteristic (ROC) curve analysis was performed to determine the effectiveness of treatment options. A value of p<0.05 was considered significant for statistical significance.
Results
Of the 103 patients with elevated hemostasis parameters, 58 (56%) were female and 45 (44%) were male. Seventy-seven of the patients (74.8%) had a history of warfarin use. 51 (49.5%) of the patients received FFP and 52 (50.5%) PCC treatment. While 47 (45.6%) patients applied due to hemorrhage, this was followed by 13 (12.6%) patients for laboratory follow-up. No treatment-related complications developed in any of the patients. Of the patients with bleeding, 8 (7.8%) had hematemesis, 9 (8.7%) had melena, 6 (5.9%) had hematochezia, and 8 (7.8%) had hematuria (Table 1).
The mean age of 103 patients who received FFP or PCC treatment was 67.31±13.17 years. INR2 values were 2.42±1.01 in the FFP group and 1.95±0.71 in the PCC group. The correlation of recorded PT and INR values with applied treatment options was significant. The percentages of decrease in INR after treatment were 66.91±19.66 (%) in all groups, 60.28±19.76 (%) in the FFP group, and 73.41±17.42 (%) in the PCC group (p=0.001, Table 2).
According to the hospitalization status of the patients; 47 (45.6%) were discharged from the emergency department (DED), 49 (47.6%) were relevant service hospitalizations (RSH), and 7 (6.8%) were in the intensive care hospitalization group. None of the patients presenting with altered consciousness could be discharged from the emergency department. In the DED group, 20 (42.6%) patients received FFP and 27 (57.4%) patients received PCC treatment (Table 3).
In the correlation analysis of the applied treatment option with the variables, there was a strong positive correlation between the decrease in INR% and the treatment option (p=0.001, Table 4).
In the ROC curve analysis of the INR % change of FFP, the area under curve (AUC): 0.286, with a 95% confidence interval (CI) of 0.187-0.385, sensitivity: 86.5%, specificity: 64.7%, (p=0.001) (Figure 1). In the ROC curve analysis of PCC % change in INR; AUC: 0.714, 95% CI: 0.615-0.813, sensitivity: 96.2%, specificity: 88.2%, (p=0.001) (Figure 2). In addition, the distribution of the percent decrease in INR of FFP and PCC used in the treatment is given in Figure 3.
Discussion
Today, cases who present with bleeding or other complaints in emergency departments and who have high hemostasis parameters are frequently seen. Although there are partial increases due to metabolic reasons, serious elevations are also detected, especially due to the use of warfarin. The clinical spectrum of patients with elevated hemostasis parameters varies, and it is usually up to emergency clinicians to ensure that the values are in the ideal range. With correct and rapid treatment, it is possible to reduce the mortality and morbidity of patients. FFP and PCC, which are among the treatment modalities applied in an emergency, create a preferred position for the clinician.
FFP is suitable for rapid replacement in multiple coagulation deficiencies such as hepatic failure, warfarin overdose, disseminated intravascular coagulation, and massive transfusion in bleeding patients. FFP can also be used when bleeding is due to a deficiency of coagulation factors. Response to FFP treatment can be monitored by performing coagulation system examinations such as PT, INR, and aPTT (15).
PCC, whose preparations consist of human plasma; contains FII, FVII, FIX, and FX components, is also used in anticoagulant therapy with proven effectiveness. Studies show that PCC offers us not only an effective but also a safe treatment option (16,17). Studies have shown that four-factor PCCs are more effective than three-factor PCCs in the emergency department, but there is no difference with FFP in terms of effectiveness and side effects (18).
There are studies evaluating the efficacy, side effects, and prognosis of the use of PCC and FFP in different cases and circumstances. In the study of Karkouti et al. (19), the efficacy of treatment in bleeding during cardiac surgery was investigated, and it was shown that the use of PCC is appropriate because it significantly reduces the need for FFP and can have a hemostatic advantage without increasing the occurrence of adverse events. In trauma patients, a resuscitation strategy using both PCC and FFP transfusion was associated with reduced mortality compared with a resuscitation strategy involving FFP alone. In addition, PCC reduced the need for RBC transfusions compared to treatment strategies without PCC (20). Although the use of PCC is considered an effective and recommended practice in general, On the other hand, there are researchers who argue that the use of PCC should be avoided in all patients with high INR values caused by vitamin K antagonists and that it can only be used in cases requiring emergency surgery due to serious, life-threatening bleeding (21).
The most important factor for bleeding risk is the INR level, which is above the treatment levels. It has been stated that when the INR level rises from 2-3 to 3-4.5, the risk of bleeding increases 2 times, and when it is between 4.5-6, it increases 4 times. Every 0.5 increase in INR levels increases the risk of major bleeding by 1.43 (22). In a study by Kaya et al. (23) in which they evaluated the use of PCC in an emergency department, the median INR value of the patients was 8.96. In our study, the median INR value of the patients who applied similarly to other studies was 8.85±4.83 and 77 (74.8%) were patients using warfarin for different reasons.
Elderly patients are more susceptible to anticoagulant effects and bleeding than younger patients. In cases over 40 years of age using warfarin, it has been shown that there is a 46% increase in the rate of major bleeding with every 10 years of age. The presence of additional diseases also contributes to this situation (22). Apart from drug efficacy in studies, the condition and comorbid diseases are also important because most of the patients are elderly. It is noteworthy that patients who applied to the emergency department used warfarin, and had high INR values were mostly older. In a similar study, Sarode et al. (4) found the mean age to be 68 years, whereas Barillari et al. (24) reported 76 years. The mean age of the patients in our study was 67 years, which was correlated with the others. Although some studies did not report significant differences in the gender distribution of patients, Keren et al. (25). In their study, the rate of female patients was 56%, similar to our study (26). We think that the important reason for the slightly higher female gender is the incidence of atrial fibrillation and the use of warfarin.
When the complaints of patients who were anticoagulated with warfarin were evaluated, it was shown that the most frequently affected system was the gastrointestinal system (38.5%) (27). In the study conducted by Sayhan et al. (28), it was seen that 16.9% of the patients presented with mostly gastrointestinal bleeding. In our study, bleeding was detected in 47 (45.6%) of all patients, and gastrointestinal system bleeding was found in 23 (31.4%) of them. In addition to the complaints at presentation, nausea and vomiting were present in 11 (10.7%) of the patients. The presence of nausea and vomiting, especially in patients using warfarin, should also suggest an elevated INR.
As a general rule, patients with severe or life-threatening bleeding require a rapid, complete reversal of the effect of warfarin; patients with no bleeding or minor bleeding, especially if the risk of thrombosis is high, can only be followed by discontinuing warfarin. International guidelines recommend the use of PCCs instead of FFP for reversing acute vitamin K antagonism in clinical bleeding (29,30). The risk of bleeding is greatest in the initial phase of treatment. Bleeding rates per year in randomized studies are between 1 and 3%. The most dangerous bleeding for most patients is intracerebral hemorrhage, which can be fatal or cause permanent neurological deficits (31). In the study by Steiner et al. (32), four-factor PCC was found to be superior to FFP in normalizing INR. It has been observed that faster INR normalization leads to smaller hematoma development. The results support the use of PCC instead of FFP in intracranial hemorrhage (32). In our study, PCC was applied to two of the four patients with intracranial hemorrhage, and it was found that success was achieved in terms of more appropriate reference values in INR normalization.
Life-threatening bleeding due to an overdose is relatively low. In his treatment, firstly, stopping warfarin and controlling it by transfusion in the emergency resulted in low hospitalization rates. In some studies, it is recommended that patients in this situation be treated by emergency services and called for necessary controls in order not to increase the cost of the hospital further (33). In our study, 47 (45.6%) patients were successfully treated in the emergency room and discharged. Appropriate dosing was performed, and they were called for control.
PCC was found to be more effective than FFP in normalizing INR and facilitating coagulation. A study of patients with mechanical heart valve disease using warfarin showed that more patients in the PCC group than in the FFP group achieved the ideal INR. The mean INR value before the PCC application was 4.02±1.07 and the mean INR value before the FFP application was 4.88±1.3. However, the mean INR value decreased to 2.51 in the first 48 hours after PCC application (34). In another study, while the mean INR value before PCC was 2.92 (2.54), the mean INR value after PCC was reported as 1.47 (0.44). The mean difference was 1.54 (2.89), which reached statistical significance (p=0.005) (35). In our study, control INR values were 2.42±1.01 in the FFP group and 1.95±0.71 in the PCC group. In addition, the percentage decrease in INR was 60.28±19.76 (%) in the FFP group and 73.41±17.42 (%) in the PCC group. There were no complications related to the application in both groups. The results of our study showed ideal and safe results in the same direction as other studies in terms of PCC’s efficiency and bringing hemostasis parameters to the ideal range.
Compared to the FFP application, fewer thrombotic complications and transfusion reactions were listed as reasons supporting the use of PCC in cases with warfarin overdose. Cruz et al. reported 7.1% thrombotic complications with PCC given after warfarin use (36). In a study using four-factor PCC, the thrombotic complication rate was reported as 1.8% (95% CI 1.0-3.0) (37). In addition, it is recommended to use PCC by considering the benefit-harm balance (26). In our study, no thromboembolic event was detected in any of our cases. The fact that long-term clinical follow-ups were not performed or cases with early-term mortality could not be evaluated for complications may have affected the results.
In a meta-analysis (37), the overall mortality rate due to warfarin overdose was reported as 10.6% (95% CI 5.9-16.6%). In patients who had PCC indications after warfarin use, 30-day mortality was reported as 22.9% (36). In our study, no mortality was observed during follow-up and treatment in the emergency department. This may show that the treatments applied do not have any mortal complications and that the treatment process has developed quite positively in terms of high hemostasis parameters today.
Study Limitations
The retrospective nature of the study was an important limitation. In addition, the limitations of the study are that it is a single-center and the factors that will affect mortality after PCC treatment (additional diseases of the cases, additional drugs used, surgical applications for bleeding control, additional medical treatments given during follow-up). Despite these limitations, clear and efficient analysis of numerical laboratory parameters before and after treatment, and objective interpretation of treatment efficacy are the strengths of the study. In addition, we believe that it contributes positively to the literature in terms of giving an idea about the choice of treatment in these cases, which are frequently encountered and treated in emergency services.
Conclusion
Both FFP and PCC treatments can be safely applied to patients with elevated hemostasis parameters in emergency departments. Recent studies and the result of our study show that PCC is preferable to FFP because it is easier to apply, acts faster, and provides more ideal coagulation parameter levels. Further studies are needed to reveal the cost, efficacy, and safety dimensions of both treatment options.